VENTILATION

         
Number 05R0466   MIC: STR
Company: STARCRAFT MARINE   Company Official: DRG
Model Name: AURORA 2000 IO   Model Year: 2005
Problem 1: VENTILATION      
Problem 2: VENTILATION      
HIN STR85114A505   Case Open Date: 3/3/2005
Disposition: CLOSED   Case Close Date: 10/24/2007
Units 556   Campaign Open Date 3/3/2005
Boat Type 11   Campaign Close Date 10/24/2007
Severity: L   Last Date: 3/6/2007
Comments:  
DN ISSUE 1.THE NATURAL SUPPLY AND EXHAUST VENTILATION AREA SHOULD BE A MINIMUM OF 12.96 SQ.IN. EACH. TWO 3-INCH SUPPLY OPENINGS AND TWO 3-INCH EXHAUST HOSES WERE INSTALLED FOR AN AGGREGATE SUPPLY OPENING OF 14.2 SQ.IN AND AN AGGREGATE EXHAUST OPENING OF 14.2 SQ.IN. HOWEVER!@ DECORATIVE GRILLS INSTALLED ON BOTH THE SUPPLY AND EXHAUST OPENINGS REDUCED THIS AREA FROM 14.2 SQ.IN. TO 8.3 SQ.IN. FP ISSUE 2. AN OPENING IN THE BULKHEAD AND DECK LOCATED BETWEEN THE FUEL TANKAND ENGINE COMPARTMENTS EXCEEDED 2% OF THAT BULKHEAD AND DECK AREA. 050404 ASSIGNED 050016S TO SMOKERCRAFT PORTION OF THIS CAMPAIGN. RECD CUR 344/556 UNITS CORRECTED. 10/24/07 CAMPAIGN CLOSED AFTER NO PROGRESS FOR 6 MONTHS.