FUEL SYSTEM

         
Number 05R0615S   MIC: VIC
Company: MARINE TECHNOLOGY INC   Company Official: RAB
Model Name: 39RP   Model Year: N/A
Problem 1: FUEL SYSTEM      
Problem 2: VENTILATION      
HIN N/A   Case Open Date: 5/12/2005
Disposition: CLOSED   Case Close Date:
Units 18   Campaign Open Date 6/21/2005
Boat Type 11   Campaign Close Date 6/8/2010
Severity: L   Last Date: 6/8/2010
Comments:  
THE FUEL TANKS’ TOPS ABOVE ENGINES’ CARBURETOR INLETCONNECTIONS. NO ANTI-SIPHON DEVICE OR ELECTRICALLY OPERATED FUEL STOP VALVE AT THE TANKS’ WITHDRAWAL FITTINGS. INSUFFICIENT NATURAL EXHAUST VENTILATION FOR EACH OF THE PORT AND STARBOARD ENGINE COMPARTMENTS. 3/19/07 CUR REC'D. 7 UNITS CORRECTED. 6/25/07 REC'D CUR 7/18 UNITS CORRECTED. SENT NEW REQ. SENT OVERDUE CUR LTR 12/15/08. CUR 8 REC'D 1/12/09 7/18 CORRECTED. SPOKE WITH MR ASHBY, CUR BEING SENT SOON. JDH, COLLECTED EMAIL FROM HIM 5/20/09. RECEIVED EMAIL FROM MR. ASHBY WITH SCAN OF CUR, 7/18 CORRECTED, RESPONDED WITH ACKNOWLEDGEMENT EMAIL WITH BLANK CUR ATTACHED JDH 5/20/09. CUR 9 RECD 7/18 CORR. NEX DUE 9/2/09. IF AT NEXT CUR, NO IMRPOVEMENT, WORK WITH MNF TO FIGURE OUT HOW TO IMPROVE.EMAILED MNF 2/23/10 JDH FOR UPDATED CUR, ATTACHED A BLANK FORM.RECD CUR FROM MNF 2/24/10 JDH 7/18 CORR. EMIALED MNF TO INFORM OF POSSIBLE CLOSING. RECD CUR 18 FROM MNF 7/18 CORR. EMILAED LUPER TO RECOMMEND CLOUSRE 6/2/10 JDH. DRAFTED CAMPAIGN CLOSURE LETTER, 6/8/10 JDH.