ELECTRICAL SYSTEM

         
Number 06R1393S   MIC: IGW
Company: IMAR GROUP LLC   Company Official: RAB
Model Name: REVO 6.7!@ 22 INBOARD   Model Year: 2006
Problem 1: ELECTRICAL SYSTEM      
Problem 2: FUEL SYSTEM      
HIN US-IGWW0642C606   Case Open Date: 5/23/2006
Disposition: CLOSED   Case Close Date:
Units 24   Campaign Open Date 7/10/2006
Boat Type 12   Campaign Close Date 5/7/2008
Severity: L   Last Date: 4/4/2007
Comments:  
"ELECTRICAL COMPONENTS OUTSIDE THE ENGINE COMPART. ARE NOT ISOLATED FROM FUEL SOURCES. A NON-IGNITION PROTECTED AUDIO SYSTEM WAS INSTALLED IN A SPACE COMMON TO THE ENGINE COMPART.!@ BOTH SPACES NOT BEING OPEN TO THE ATMOSPHERE. THE FUEL FILL RECEPTACLE IS LOCATED ONLY 1"" FROM THE ENGINE COMPARTMENT HATCH OPENING!@ AND THE MNF HAD NOT CONDUCTED A GAS OVERFLOW TEST. BOAT DID NOT HAVE ADEQUATE SIZE NATURAL SUPPLY AND EXHAUST VENT. GAS ENGINE AND ADJUOINING COMPARTMENTS HAVE NET COMPART. VOL. OF APPROX. 208 CF!@ NOT IN ACCORDANCE WITH WITH SECTION 183.630. TWO 3 INCH DUCTS ARE PROVIDED FOR THE EXHAUST VENTS!@ WHICH RESULTS IN AN AGGREGATE OPENING OF 14.2 SQ. IN. EACH. BOAT DID NOT HAVE THE REQ. LABEL INSTALLED. CAP. LABEL INCLUDED ""US COAST GUARD CAPACITIES!@"" NOT APPLICABLE TO 22 INBOARD!@ 33CFR183. 7/12/06 RECD LETTER OF APPEAL TO CITE: 33CFR183.564. UPON REVIEW APPEAL GRANTED. 9/5/06 RECD CUR 0/24 UNITS CORRECTED. OOB PER PPG 5/7/08."