LEVEL FLOTATION

         
Number 15CG046S   MIC: IDM
Company: MOMARSH INC   Company Official: PLC
Model Name: 12 FG DUCK   Model Year: 2015
Problem 1: LEVEL FLOTATION      
Problem 2:      
HIN IDM07730E515   Case Open Date: 12/4/2015
Disposition: OPEN   Case Close Date:
Units   Campaign Open Date 11/8/2016
Boat Type   Campaign Close Date
Severity: l   Last Date: 11/8/2016
Comments:  
Failed 3 LF tests by small margin (15lbs). Mailed DNR and CUR forms 3/24/16 JT.040616 - EXPLAINED TEST REPORT, AND RECALL PROCEDURE TO MNF POC, WHO IS COMTEMPLATING A REPAIR KIT AND RETEST BEFORE RECALL. PLC.042716 - MNF PROPOSED TO LOWER THE MPC FROM 425 TO 400LBS; RESP TO MNF THAT IT PROBABLY WOULD NOT PASS. BOAT NEEDS A DEDUCTION OF AT LEAST 120 LBS BEFORE RETEST TO CONFIRM. PLC. Mailed retest and everything passed, mnf needs to start recall process 6/8/16 JT.092016 - MNF SUB INCOMPLETE DNR AND BRIEF RECALL LETTER. EXPLAINED THAT DNR NEEDS TO BE COMPLETE (WITH AFFECTED HINS) AND LETTER MORE DETAILED BEFORE CAMPAIGN CAN START. PLC. Sent email 11/3/16 JT.110816 - MNF SUB CORRECT DNR, DEFECT NOTIF LETTER. CAMPAIGN MAY START. PLC.